EARLY ACCESS WINTER 2026Development Engine
Nine cultures, thousands of in‑process data points, one instrument.
A benchtop lab-in-a-box that runs cell culture and records everything it does. Load the cassettes, program the process, walk away, come back to data.
Nine independent cultures run side by side
Reagents held cold on board, warmed before use
Program your process on a laptop then walk away
Remote monitoring while the run is in progress
Incubation, gassing, feeding, and analytics on one bench
Air, CO₂, and N₂ blended per culture
Imaging, Raman, pH, and DO read in place on every cassette
Low-shear, tilt-based mixing
Inside the instrument.
1
2
3
4
5
6
01
Bioreactor bay
Nine cassette positions, temperature controlled, loaded from the front.
02
Refrigerated reagents
Nine bottle positions held cold above the bay, sterile tubing to each cassette.
03
Fluid and gas control
Per-cassette pumping, valving and Air / CO₂ / N₂ blending, with automated mixing.
04
Analytics head
A single gantry-mounted head travels the bay, measuring each cassette in turn.
05
Control screen
Run status, live values, and operator prompts at the bench, mirrored remotely.
06
Waste compartment
Easy-access waste, emptied from the front without interrupting a run.
One instrument, multiple scales.
The bioreactor bay takes small, intermediate and large cassettes, in the combinations below.
9 small
3 intermediate
1 large + 3 small
2 intermediate + 3 small
1 intermediate + 6 small
What you measure, on every culture.
Every bioreactor is measured in place, without opening the cassette and without consuming a sample. Raw signals are retained alongside the derived metrics.
Measurement
What you get
Method
Cell imaging
Images of the culture through the run, multi-plane and multi-location, reviewable frame by frame
15× brightfield imaging through the cassette wall
Cell count
Cell density per cassette as a continuous time series, from inoculation to end of run
Imaging, cross-referenced with Raman
Viability
Viable fraction tracked over time, without pulling a sample
Image analysis, MFX-trained models
Glucose & lactate
Metabolite concentrations on demand, with full spectra retained
Non-contact Raman spectroscopy through the cassette wall. Full Raman spectrum available for every reading
pH & dissolved oxygen
Continuous environmental time series per cassette, with temperature across the bay
Single-use non-contact optical patches
Manual aseptic sampling remains available on any cassette at any time. Every signal is logged as time series.
Specifications
Bring a workflow, leave with a process.
Book a demo or an evaluation, at our facility or yours.